DS1818-5+

Symbol Micros: UIDS181805
Contractor Symbol:
Case : TO92
MCU Supervisor, Act.Low / Open-Drain, Vthr 3.0÷3.15V, Man.RESET, -40÷85°C
Parameters
Threshold voltage: 3,06V
Reset active high voltage level: None
Reset active low voltage level: Open drain
Manual RESET: YES
Watchdog: NO
Manufacturer:: Maxim Manufacturer part number: DS1818-5+ RoHS Case style: TO92bul  
In stock:
50 pcs.
Quantity of pcs. 1+ 3+ 10+ 20+ 50+
Net price (EUR) 1,1000 0,7891 0,6217 0,5667 0,5237
Add to comparison tool
Packaging:
50
Threshold voltage: 3,06V
Reset active high voltage level: None
Reset active low voltage level: Open drain
Manual RESET: YES
Watchdog: NO
Detailed description

The DS1818 circuit is used for monitoring the supply voltage drop in 3V-powered microprocessor systems. If the supply voltage drops below a preset threshold value, the circuit will trigger a reset of the microprocessor, preventing it from continuing improper operation. The delay time from exceeding the threshold value to the activation of the RESET signal is a maximum of 5µs. When the supply voltage returns to the appropriate level, the circuit releases the RESET signal after about 150ms, allowing the microprocessor to stabilize before normal operation.

The DS1818 circuit also features the option to manually reset the microprocessor using an external button. After releasing the button, the RESET signal is maintained in the active state for an additional 150ms to eliminate the effects of contact bounce.