Gas discharge tube; 75VDC
Impulse discharge current 10/1000us; 200A: 300 times; dimensions: 6x8mm; 2 electrodes; 10GR; 2 leads: axial; THT
|
||||||||||||||||||||||||
Manufacturer:
BOCHEN Manufacturer part number: Case style: Rys.OP 075 |
In stock:
300 pcs. |
|||||||||||||||||||||||
|
Packaging: 100/700 Quantity (multiple 1) |
N/A | Anti-Surge | THT | 6x8mm | 75V | N/A | Axial | 2 | 10GOhm | 2 | |||||||||||||
Manufacturer:
BOCHEN Manufacturer part number: Case style: Rys.OP 075 |
In stock:
7 pcs. |
|||||||||||||||||||||||
|
Packaging: 100/600 Quantity (multiple 1) |
N/A | Anti-Surge | THT | 6x8mm | 75V | N/A | Axial | 2 | 10GOhm | 2 | |||||||||||||
Manufacturer:
BOCHEN Manufacturer part number: Case style: Rys.OP 075 |
In stock:
10 pcs. |
|||||||||||||||||||||||
|
Packaging: 100/500 Quantity (multiple 1) |
N/A | Anti-Surge | THT | 6x8mm | 75V | N/A | Axial | 2 | 10GOhm | 2 | |||||||||||||
|
Item in delivery
Estimated time: 2025-04-05
Quantity of pieces: 600
|
|||||||||||||||||||||||
|
Item in delivery
Estimated time: 2025-03-10
Quantity of pieces: 300
|
|||||||||||||||||||||||
Gas discharge tube; 90VDC
Impulse discharge current 10/1000us; 200A: 300 times; dimensions: 6x8mm; 2 electrodes; 10GR; 2 leads: axial; THT
|
||||||||||||||||||||||||
Manufacturer:
BOCHEN Manufacturer part number: Case style: Rys.OP 090 |
In stock:
488 pcs. |
|||||||||||||||||||||||
|
Packaging: 100/500 Quantity (multiple 1) |
N/A | Anti-Surge | THT | 6x8mm | 90V | N/A | Axial | 2 | 10GOhm | 2 | |||||||||||||
Gas discharge tube; 230VDC
Impulse discharge current 10/1000us; 200A: 300 times; dimensions: 6x8mm; 2 electrodes; 10GR; 2 leads: axial; THT
|
||||||||||||||||||||||||
Manufacturer:
BOCHEN Manufacturer part number: Case style: Rys.OP 230 |
In stock:
1500 pcs. |
|||||||||||||||||||||||
|
Packaging: 100 Quantity (multiple 1) |
N/A | Anti-Surge | THT | 6x8mm | 230V | N/A | Axial | 2 | 10GOhm | 2 | |||||||||||||
Gas discharge tube; 350VDC
Impulse discharge current 10/1000us; 200A: 300 times; dimensions: 6x8mm; 2 electrodes; 10GR; 2 leads: axial; THT
|
||||||||||||||||||||||||
Manufacturer:
BOCHEN Manufacturer part number: Case style: Rys.OP 350 |
In stock:
1200 pcs. |
|||||||||||||||||||||||
|
Packaging: 100 Quantity (multiple 1) |
N/A | Anti-Surge | THT | 6x8mm | 350V | N/A | Axial | 2 | 10GOhm | 2 | |||||||||||||
Gas discharge tube; 470VDC
Impulse discharge current 10/1000us; 200A: 300 times; dimensions: 6x8mm; 2 electrodes; 10GR; 2 leads: axial; THT
|
||||||||||||||||||||||||
Manufacturer:
BOCHEN Manufacturer part number: Case style: Rys.OP 470 |
In stock:
100 pcs. |
|||||||||||||||||||||||
|
Packaging: 100/600 Quantity (multiple 1) |
N/A | Anti-Surge | THT | 6x8mm | 470V | N/A | Axial | 2 | 10GOhm | 2 | |||||||||||||
Gas discharge tube; 500VDC
Impulse discharge current 10/1000us; 200A: 300 times; dimensions: 6x8mm; 2 electrodes; 10GR; 2 leads: axial; THT
|
||||||||||||||||||||||||
Manufacturer:
BOCHEN Manufacturer part number: Case style: Rys.OP 500 |
In stock:
300 pcs. |
|||||||||||||||||||||||
|
Packaging: 100/300 Quantity (multiple 1) |
N/A | Anti-Surge | THT | 6x8mm | 500V | N/A | Axial | 2 | 10GOhm | 2 | |||||||||||||
Gas discharge tube; 600VDC
Impulse discharge current 10/1000us; 200A: 300 times; dimensions: 6x8mm; 2 electrodes; 10GR; 2 leads: axial; THT
|
||||||||||||||||||||||||
Manufacturer:
BOCHEN Manufacturer part number: Case style: Rys.OP 600 |
In stock:
996 pcs. |
|||||||||||||||||||||||
|
Packaging: 100/1000/4000 Quantity (multiple 1) |
N/A | Anti-Surge | THT | 6x8mm | 600V | N/A | Axial | 2 | 10GOhm | 2 | |||||||||||||
Gas discharge tube; 700VDC
Impulse discharge current 10/1000us; 200A: 300 times; dimensions: 6x8mm; 2 electrodes; 10GR; 2 leads: axial; THT
|
||||||||||||||||||||||||
Manufacturer:
BOCHEN Manufacturer part number: Case style: Rys.OP 700 |
In stock:
346 pcs. |
|||||||||||||||||||||||
|
Packaging: 100/300 Quantity (multiple 1) |
N/A | Anti-Surge | THT | 6x8mm | 700V | N/A | Axial | 2 | 10GOhm | 2 | |||||||||||||
Gas discharge tube; 800VDC
Impulse discharge current 10/1000us; 200A: 300 times; dimensions: 6x8mm; 2 electrodes; 10GR; 2 leads: axial; THT
|
||||||||||||||||||||||||
Manufacturer:
BOCHEN Manufacturer part number: Case style: Rys.OP 800 |
In stock:
300 pcs. |
|||||||||||||||||||||||
|
Packaging: 100/700 Quantity (multiple 1) |
N/A | Anti-Surge | THT | 6x8mm | 800V | N/A | Axial | 2 | 10GOhm | 2 | |||||||||||||
Gas discharge tube; 75VDC
Impulse discharge current 10/100us; 100A: 300 times; dimensions: 10x8mm; 3 electrodes; 10GR; 3 leads: axial; THT
|
||||||||||||||||||||||||
Manufacturer:
BOCHEN Manufacturer part number: Case style: Rys.OP3-075 |
In stock:
0 pcs. |
|||||||||||||||||||||||
|
Packaging: 100/400 Quantity (multiple 1) |
N/A | Anti-Surge | THT | 10x8mm | 75V | N/A | Axial | 3 | 10GOhm | 3 | |||||||||||||
Gas discharge tube; 90VDC
Impulse discharge current 10/100us; 100A: 300 times; dimensions: 10x8mm; 3 electrodes; 10GR; 3 leads: axial; THT
|
||||||||||||||||||||||||
Manufacturer:
BOCHEN Manufacturer part number: Case style: Rys.OP3-090 |
In stock:
196 pcs. |
|||||||||||||||||||||||
|
Packaging: 100 Quantity (multiple 1) |
N/A | Anti-Surge | THT | 10x8mm | 90V | N/A | Axial | 3 | 10GOhm | 3 | |||||||||||||
Gas discharge tube; 230VDC
Impulse discharge current 10/100us; 100A: 300 times; dimensions: 10x8mm; 3 electrodes; 10GR; 3 leads: axial; THT
|
||||||||||||||||||||||||
Manufacturer:
BOCHEN Manufacturer part number: Case style: Rys.OP3-230 |
In stock:
400 pcs. |
|||||||||||||||||||||||
|
Packaging: 100 Quantity (multiple 1) |
N/A | Anti-Surge | THT | 10x8mm | 230V | N/A | Axial | 3 | 10GOhm | 3 | |||||||||||||
PGB102ST23WR Littelfuse Gas discharge tube
Gas discharge tube; 24V; 150V; 24VDC; SMD; SOT-23-3; dimensions: 3x2.24x0.69mm
|
||||||||||||||||||||||||
In stock:
100 pcs. |
||||||||||||||||||||||||
|
Packaging: 100 Quantity (multiple 1) |
Littelfuse | Anti-Surge | SMD | 3x2.24x0.69mm | 24V | SOT-23 | -65°C ~ 125°C | N/A | 0 | 0 | |||||||||||||
B88069X1640T902 TDK Gas discharge tube
Gas discharge tube; 90V; dimensions: 5,7x5,4mm; 2 electrodes; 90V; 1GOhm; SMD
|
||||||||||||||||||||||||
In stock:
100 pcs. |
||||||||||||||||||||||||
|
Packaging: 500 Quantity (multiple 1) |
TDK | Anti-Surge | SMD | 5,7x5,4mm | 90V | N/A | -40°C ~ 90°C | N/A | 0 | 1 GOhm | 2 | ||||||||||||
B88069X2010S102 TDK Gas discharge tube
Gas discharge tube; 470V; dimensions: 8x7,9mm; 2 electrodes; 470V; 10GOhm; 2 leads: axial; THT
|
||||||||||||||||||||||||
Manufacturer:
EPCOS Manufacturer part number: B88069X2010S102 RoHS Case style: Rys.B88069X2010 |
In stock:
100 pcs. |
|||||||||||||||||||||||
|
Packaging: 100 Quantity (multiple 1) |
TDK | Anti-Surge | THT | 8x7,9mm | 470V | N/A | -40°C ~ 125°C | Axial | 2 | 10GOhm | 2 | ||||||||||||
2036-23-SM-RPLF-H Bourns Gas discharge tube
Gas discharge tube; 230V; 230VDC; 10kA; 25%; 2pF; 3 electodes; SMD; diameter: 5mm; length: 7,3mm
|
||||||||||||||||||||||||
In stock:
100 pcs. |
||||||||||||||||||||||||
|
Packaging: 400 Quantity (multiple 1) |
Bourns | Anti-Surge | SMD | 5x7,5mm | 230V | -55°C ~ 125°C | 3 | ||||||||||||||||
CG90L Littelfuse Gas discharge tube
Gas discharge tube; 90V; dimensions: 8x6mm; 2 electrodes; 90V; 10GOhm; 2 leads: axial; THT
|
||||||||||||||||||||||||
In stock:
100 pcs. |
||||||||||||||||||||||||
|
Packaging: 50/100 Quantity (multiple 1) |
Littelfuse | Anti-Surge | THT | 6x8mm | 90V | N/A | -40°C ~ 90°C | Axial | 2 | 10GOhm | 2 | ||||||||||||
PGB1010402KR Littelfuse Gas discharge tube
Gas discharge tube; 12V; SMD; 0402; 250V; 0,04pF; 8kV; dimensions: 0.99x0.51x0.31mm; operating temperature: -65°C~125°C
|
||||||||||||||||||||||||
In stock:
1000 pcs. |
||||||||||||||||||||||||
|
Packaging: 1000 Quantity (multiple 1) |
Littelfuse | Anti-Surge | SMD | 0.99x0.51x0.31mm | 12V | 0402 | -65°C ~ 125°C | N/A | 0 | ||||||||||||||
Gas discharge tube; 150VDC
Impulse discharge current 10/1000us; 200A: 300 times; dimensions: 6x8mm; 2 electrodes; 10GR; 2 leads: axial; THT
|
||||||||||||||||||||||||
N/A | Anti-Surge | THT | 6x8mm | 150V | N/A | Axial | 2 | 10GOhm | 2 | |||||||||||||||
|
Item available on a request
|
|||||||||||||||||||||||
Gas discharge tube; 250VDC
Impulse discharge current 10/1000us; 200A: 300 times; dimensions: 6x8mm; 2 electrodes; 10GR; 2 leads: axial; THT
|
||||||||||||||||||||||||
N/A | Anti-Surge | THT | 6x8mm | 250V | N/A | Axial | 2 | 10GOhm | 2 | |||||||||||||||
|
Item available on a request
|
|||||||||||||||||||||||
Gas discharge tube; 150VDC
Impulse discharge current 10/100us; 100A: 300 times; dimensions: 10x8mm; 3 electrodes; 10GR; 3 leads: axial; THT
|
||||||||||||||||||||||||
N/A | Anti-Surge | THT | 10x8mm | 150V | N/A | Axial | 3 | 10GOhm | 3 | |||||||||||||||
|
Item available on a request
|
|||||||||||||||||||||||
PGB1010603MR Littelfuse Gas discharge tube
Gas discharge tube; 24V; 150V; 24VDC; SMD; 0803; dimensions: 1.66x0.84x0.36mm
|
||||||||||||||||||||||||
Littelfuse | Anti-Surge | SMD | 1.66x0.84x0.36mm | 24V | 0803 | -65°C ~ 125°C | N/A | 0 | 0 | |||||||||||||||
|
Item available on a request
|
|||||||||||||||||||||||
B88069X3070C203 TDK Gas discharge tube
Gas discharge tube; 500V; dimensions: 6x8,1mm; 3 electrodes; 500V; 10GOhm; THT
|
||||||||||||||||||||||||
TDK | Anti-Surge | THT | 6x8,1mm | 500V | N/A | -40°C ~ 90°C | 10GOhm | 3 | ||||||||||||||||
|
Item available on a request
|
|||||||||||||||||||||||
CG590LS Littelfuse Gas discharge tube
Gas discharge tube; 90V; dimensions: 5x5mm; 2 electrodes; 90V; 10GOhm; 2 leads: profiled; SMD
|
||||||||||||||||||||||||
Littelfuse | Anti-Surge | SMD | 5x5mm | 90V | N/A | -40°C ~ 90°C | Profiled | 2 | 10GOhm | 2 | ||||||||||||||
|
Item available on a request
|
Surge Protectors
We strive to ensure that our customers find all the products they need with us. Our range of essential components for electrical and electronic systems is comprehensive. Surge protectors are also included in our offering.
What is a Surge Protector?
It is worth starting with the fact that surge protectors are referred to by many different names. Sometimes the abbreviated term – surge protector is used. Other times, they are called lightning arresters or surge limiters. Ultimately, they are always devices whose purpose is to prevent the occurrence of a surge or at least mitigate its negative effects by limiting the frequency and duration of the so-called follow-up current.
Types of Surge Protectors
In our offer, you will find various surge protectors. We have components from three main categories, namely:
- disconnection,
- limiting,
- combined.
A disconnection surge protector is a device equipped with a spark gap, which is its basic component. This equipment shorts the terminals, allowing current to flow when a specified voltage value is exceeded. When the voltage remains within the norm, these surge protectors do not conduct electricity.
Limiting models work with varistors. These devices absorb the impulse energy, leading to the disconnection of electrical equipment when the permissible voltage limit is exceeded.
On the other hand, combined surge protectors are devices that combine the features of disconnection and limiting models. They are characterized by no current flow when the voltage is within the norm and the fact that they completely eliminate follow-up current.
How to Connect Surge Protectors?
You might be wondering how to connect surge protectors? As you browse our range, you will notice how diverse the models of surge protectors are. This means that the answer to the installation question is not straightforward. However, in every case, it is worth remembering some basic principles.
First and foremost, remember that surge protectors are installed in the main distribution board. This is where the main grounding rail is located. Additionally, surge protectors can be easily inspected when installed in the distribution board. An alternative is to install the device on a cable junction. However, this solution is not recommended due to the lower effectiveness of the protector in such a location.
When installing a surge protector, remember its proper placement in the distribution board. It is recommended to place it second, immediately after the main switch. Next, install the phase failure detector, followed by differential and overload protections.
Now you know what surge protectors are and what they are used for. We have also provided you with tips on how to connect surge protectors. All that remains is to familiarize yourself with the products we offer and choose the one that meets your individual needs.